Omnes Categoriae
Color doppler ultrasound scanner

Pagina Principalis /  Products  /  Ultrasonus Scansor  /  Color doppler ultrasound scanner

Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8
Cordis Echo Ultrasound YJ-T8

Cordis Echo Ultrasound YJ-T8

* Continua unda Doppler imaginis (CW)
* Anatomicus 3 M Modus imaginis
* Automatus IMT (intima-media crassitudo) Mensuratio
* 3D/4D Imagines
* Trapezoidalis Imago & Panoramicus Imago
* Suppressiones Stellae Rumor

Brochure Producti: Descarga

  • Video
  • Introductio
  • Parametrum
Video

Introductio

Vigor Echo Ultrasound
Professionale Machina Ultrasonica Cardiaca
Ultrasonus altissimus YJ-T8 applicat resolutionem imaginis excellentem, operationem intelligentem, design ergonomicum et interactionem intimam inter hominem et machinam ut unum organicum totum

Parametrum
1: Summarium specificatorum principalium et systematis ultrasoni coloris Doppler carrae typi
1.1 Tela principalis totius digitalis coloris ultrasoni Doppler carram typum
1.2 Systema operationis hospitis ultrasonici: Systema operationis Windows
1.3 Applicationes:
Venter, obstetricia, gynaecologia, cor, renalis systema, parva organa, superficialia, vascula, paediatrica, recens nati, musculorum ossiumque
1.4 Sondae:
Sonda convexus, Sonda transvaginalis, Sonda linearis, Sonda microconvexa, Sonda cardiaca, 4D Volumen
probe
1.5 Applicatio et relatio:
Abdominalis, OB, GYN, Cardiacus, Urinarius, Partes parvae, Superficialis, Vasculares, Puericultura, Pacchetti software mensurationum avancatarum, pacchetti software relationum, pacchetti software gestionis casuum, etc.
☆1.6 carotis arteriae intima mensura crassitiei(IMT)
☆1.7 Automata spectrale involucrum mensura
1.8 Plena digitalis transmissio et receptio fasciculi synthetizatoris
1.9 Imaging coloris Doppler(C)
1.10 Imago Fluctuationis Doppler (PW)
☆1.12 Imago Contrastus Coherentis (CCI)
1.12 Imago Continui Fluctuationis Doppler (CW)
☆1.13 B\/C\/D Imago realis trium synchronicorum
☆1.14 Imago Doppler potentiae (PDI)
☆1.15 Imago directa potentiae Doppler (DPDI)
1.16 Imago modi M
☆1.17 Imago modi M anatomicus
☆1.18 Imago modi M Doppler coloratus
☆1.19 Elastographia
☆1.20 Imago Doppler Tissularis (TDI)
☆1.21 Imago taxonomiae distensionis (SRI)
1.22 Imago harmonica tissularis (THI)
1.23 Imago harmonica fusionis (FHI)
1.24 Imago reducta maculis (SRI)
☆1.25 Imago panoramica
☆1.26 Imago deviationis
☆1.27 Imago trapezoidalis
1.28 Optimizatio velocitatis adaptiva
☆1.29 Liber manus 3D
1.30 Imaging tempore reali 3D (3D/4D)
1.31 Dicom3.0
1.32 Monitor: ≥21.5 uncia, display ultrasonicus definitionis altissimae
1.33 ≥13.3 pollicis tactilis
1.34 Materialis tabula: serva imaginem in sinistra parte schermi, quae directe servari vel deleri potest.
1.35 Systema habet vim ad praesentem meliorem faciem
1.36 Praescriptio: pro diversis examinationibus viscerum, praescribitur status examinationis ad optimam imaginem, minuuntur operationis adjustmenta, et communia externa adjustmenta et combinatio regulationis.
1.37 Interfacing probus: 4
1.38 Systema Sinense et Anglicum, input Sinensis et Anglici, optionale
1.39 Profunditas:≥360mm;
1.40 Imago Extensa
1.41 Support 10 genera linguarum: CH, EN, FR.SP,PT.RU et alia
2: Probes
2.1 Probiculum convexus Frequenta Fundamentalis:2.0MHz/2.5MHz/3.5MHz/4.0MHz/5.0MHz/6.0MHz/8.0MHz/9.0MHz/10MHz
Frequenta Harmonica:
4.0MHz/4.6MHz/5.0MHz,
2.2      
Probiculus linearis
Frequenta Fundamentalis:4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3 MHz,
Frequenta Harmonica:
8.0MHz/9.2MHz/10.0MHz,
2.3 Trans-vaginalis probus Frequentia Fundamentalis:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz,
Frequenta Harmonica:
6.0MHz/7.0MHz/8.0MHz,
2.4 Micro-concavus probus Frequentia Fundamentalis:
3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz,
Frequenta Harmonica:
6.0MHz/7.0MHz/8.0MHz,
2.5 Cardiac probe Frequentia Fundamentalis:1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz,
Frequenta Harmonica:
3.4MHz/3.8MHz/4.2MHz,
2.6      
sonda volumetrica 4D
Frequentia Fundamentalis:
2.0MHz/2.5MHz/3.0MHz/3.3 MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz,
Frequenta Harmonica:
4.0MHz\/5.0MHz\/6.0MHz,
3: modus imaginis 2D
3.1 Acquis:0-100,Pasu 2 regulabilis
3.2 TGC:8 segmenta regulabilia
3.3 Punctum foci maximum:≥7, quod per totum cursum movere licet.
3.4 Reductio macularum: 0-5, 5 gradus
3.5 Syntesis spatii: 0-2, 2 gradus (probam linearem: 3 gradus, probam cordis: 0)
3.6 Dynamica: 30-300, 35 gradus, passus 5 adjustabilis
3.7 Densitas Lineae: Infima, Media, Maxima, 3 gradus
3.8 Correlatio formae: 0-4, 4 gradus
3.9 Reductio strepitus: 0-5,5 gradus
3.10 Intensificatio marginis: 0-5, 5 gradus
3.11 Vis soni: 2-10, 9 gradus
3.12 Scala cinerea: 0-67, 67 gradus
3.13 Color fictus: 0-67, 67 gradus
3.14 Stilus imaginis: Molle-Comparatio, 2 gradus
  Praesentia vocis potentia, probe frequentia, dynamicus ambitus, pseudocolor, et scala grisea aliorumve 11 parametrorum possunt adjustari
4: Modus imaginis Color Doppler
4.1 Sanguinis gain:0-100, Gradus 2
4.2 Parametri praesentatio:Velocitas,Variatio
4.3 B-Restrain (N/B restraign): 0-7, 7 gradus
4.4 Velocitas transitus:0-8, 8 gradus
4.5 Numerus Samplorum: 6-24, 7 gradus
4.6 Praeferentia Fluminis Sanguinis: 0-8, 8 gradus
4.7 Filtra: 1-6, 6 gradus
4.8 Virtus soni: 2-6, 4 gradus
4.9 Repraesentatio strepitus: 0-4, 4 gradus
4.10 Tractatus lenis: 0-4, 4 gradus
4.11 Correlatio formae: 0-6, 6 gradus
4.12 Chromatographia (Graphicus fluxus sanguinis): 0-37, 37 gradus
4.13 Densitas lineae: Inferus-Medium-Superus, 3 gradus
4.14 Frequentia: 4 gradus adjusticii
4.15 Velocitas: Minimus 0.4K, Maximus 40.5K
Probiculum convexus: 0.4K-4.3K-38.5K
Probiculum lineare: 0.4K-14.7K-39.0K
Sonda transvaginalis: 0.4K-7.8K-39.7K
Sonda volumetrica: 0.4K-4.2K-34.8K
Sonda microconvexa: 0.4K-10.3K-40.5K
sonda cardiaca: 0.4K-7.8K-39.7K
  PS: Frequentia sondae mutatur et valor frequentiae mutatur
  PS: Freqventia imaginum mutatur cum velocitate
5: Pulsus unda Doppler(PW)
1 Guadagno:0-100, passo 2
5.2 Spectrum involucrum functio: tempore reali automata spectrum involucrum, manualis spectrum involucrum, et alii modi. Systema automaticum analysat et ostendit varias datas sicut PSV, EDV, RI, PI, S/D, ACC, HR et cetera. Possit excitare aut claudere
5.3 Volume exempli:0.5mm~30mm
5.4 Anguis sanguinis:-75-75 gradus, Gradus 5
5.5 Color fictus:0-67, 67 gradus
5.6 Ambitus dynamicus:20-40, 4 gradus
5.7 Filtrum:0-9, 9 gradus
5.8 Tractamentum lenis:1-4, 4 gradus
5.9 Virtus soni: 2-5, 4 gradus
5.10 Volumen: 0-100, 10 gradus, Incrementum 10
5.11 Filtratio auditiva: 0-4, 4 gradus
5.12 Linea basis: -1.0~1.0,
5.13 Carta grisea: 0-67, 67 gradus
5.14 Velocitas scannings: 100-500, 6 gradus
5.15 PRF: Minima 0.5K, Maxima 87.5K
Sonda convexus: 0.5K-4.3K-63.3K
Sonda linearis: 0.5K-14.5K-78.4K
Sonda transvaginalis: 0.5K-8.1K-78.4K
Sondam voluminis: 0.5K-4.2K-53.8K
Sondam micro-convexa: 0.5K-10.3K-81.1K
sondam cardiacam: 0.5K-4.3K-87.5K
5.16 Frequentia: 4 gradus
  PS: Frequentia sondae mutatur et valor PRF mutatur
  PS: Frequentia sondae mutatur et valor frequentiae mutatur
6: Fluxus Continuus Doppler (CW)
6.1 Sustinet probam: Proba Cardiaca
6.2 Regulatio parametrarum modi B est commutabilis
6.3 Guadagno:0-100, passo 2
6.4 Locatio lineae sampling est regulabilis
6.5 PRF: 0.9K~36.1K
6.6 Limes:-1.0~1.0
6.7 Angulus sanguinis:-75~75 gradus
6.8 Carta grisea:0-67
6.9 Velocitas scandendi:100-300
6.10 Color fictus:0-67
6.11 Ambitus dynamicus: 20-40
6.12 Filtratio: 0-9, 9 gradus
6.13 Tractamentum suavis: 1-4
6.14 Frequentia: 2.0MHz/2.3 MHz/2.5MHz/3.0MHz, 4 gradus adjustibilis
6.15 Virtus soni: 2-5
6.16 Volumen:0-100
6.17 Filtratio Soni:0-4
☆7: Imago Anatomica M
7.1 Sustinet Probam:Proba Convexa, Proba Linearis, Proba Cordis
7.2 Regulatio parametrarum modi B est commutabilis
7.3 Guadagno:0-100, passo 2
7.4 Linea praesumptionis angulus est adjustabilis
7.5 Longitudo lineae praesumptionis est adjustabilis
7.6 Linea praesumptionis: 3, Potest singillatim ostendi vel abscondi
☆8: Fluxus sanguinis M model (MC)
8.1 Regulatio parametrarum modi B est commutabilis
8.2 Guadagnus:0-100, Gradus2
8.3 Linea angulus pro MC campione est regulabilis
8.4 Longitudo lineae pro MC campione est regulabilis
8.5 Frequentia: 4 gradus
8.6 Numerus campionum:6-24
8.7 Velocitas transitus:0-8, 8 gradus
8.8 Velocitas scannandi: 150-500
8.9 Correlatio formae: 0-6, 6 gradus
8.10 Filtri: 1-6, sex gradus
8.11 Praeferentia fluxus sanguinis: 0-8, octo gradus
8.12 Tractamentum lenis: 0-4, quattuor gradus
8.13 Mappa: 0-37, septem et triginta septem gradus
☆9: Elastographia
9.1 Regulatio parametrarum modi B est commutabilis
9.2 Guadagno:0-100, passo 2
9.3 B\/E, Duplex indicatio in tempore reali in eadem tabula
9.4 Indicatio curvae displacement probae: Sursum\/Deorsum
9.5 Indicatio barrae pressurae
9.6 Frequentia: 8-9 gradus, Regulabilis; Secundum probam indicatio
9.7 Reductio strepitus:0-2, 2 gradus
9.8 Correlatio formae:0-3, 3 gradus
9.9 Comparatio:0-13, 13 gradus
9.10 Color ficticius:0-3, 3 gradus
9.11 Non sustinet probam cordis
☆10: Imago Doppler Tissularis (TDI)
10.1 Supporto proba: Proba cardiaca
10.2 Regulatio parametrarum modi B est commutabilis
10.3 Guadagno:0-100, passo 2
10.4 Aera ROI adiustabilis
10.5 Numerus campionum:6-24
10.6 Velocitas:0.4K-8.0K
10.7 Correlatio framen:0-6,6 gradus
10.8 Praeferentia tissularis: 0-7, 7 gradus
10.9 Frequentia: 2.0MHz/2.3 MHz/2.5MHz/3.0MHz
10.10 Supportat inversionem coloris
☆11: Imago taxonomiae tensionis
11.1 Supporto proba: Proba cardiaca
11.2 Regulatio parametrarum modi B est commutabilis
11.3 Aera ROI adiustabilis
11.4 Guadagno:0-100, passo 2
11.5 Numerus exemplificatorum: 6-24, sex gradus
11.6 Media axialia: 1-4, quattuor gradus
11.7 Velocitas: 0.4K-8K
11.8 Correlatio formae: 0-6, 6 gradus
11.9 Optimizatio tissularis: 0-7, septem gradus
☆12: Imago panoramica
12.1 Supporto proba:Sonda linearis
12.2 Reductio macularum:0-5, 5 gradus
☆13: Imago deviationis
13.1 Supporto proba:Sonda linearis
13.2 Regulatio parametrarum modi B est commutabilis
13.3 Angulus deflexionis:8 gradus
13.4 Reductio macularum:0-5, 5 gradus
13.5 Ratum dynamicum:30-180,Intervallo 5
13.6 Densitas lineae:parvus-medius-magnus,3 gradus
13.7 Correlatio formae:0-4, 4 gradus
13.8 Color fictus:0-67, 67 gradus
13.9 Stilus imaginis: Molle-Comparatio, 2 gradus
13.10 Reductio strepitus:0-5, 5 gradus
13.11 Intensificatio marginis: 0-5, 5 gradus
13.12 Virtus soni: 2-10,8 gradus
13.13 Carta cinerea: 0-67,67 gradus
☆14: Imago trapezoidalis
14.1 Supportum probae: proba linearis
14.2 Regulatio parametrarum modi B est commutabilis
14.3 Angulus deflexionis:8 gradus
14.4 Reductio macularum:0-5, 5 gradus
14.5 Ratum dynamicum:30-180,Intervallo 5
14.6 Densitas lineae:parvus-medius-magnus,3 gradus
14.7 Correlatio formae:0-4, 4 gradus
14.8 Color fictus:0-67, 67 gradus
14.9 Stilus imaginis: Molle-Comparatio, 2 gradus
14.10 Reductio strepitus:0-5, 5 gradus
14.11 Intensificatio marginis: 0-5, 5 gradus
14.12 Virtus soni: 2-10,8 gradus
14.13 Carta grisea: 0-67, 67 gradus
14.14 Syntesis spatii: 0-2, 2 gradus
☆15 Imago 3D libera manus
15.1 Support probe: probus convexus, probus linearis
15.2 Modellum ostensionis: 4 imagines
15.3 Rotatio imaginis Axis X/Y/Z
15.4 Visibilitas Multi-slice
16 Imaging 4D in Tempore Reali
16.1 Support Probe: Probos 4D Volumetricus
16.2 Regulatio parametrarum modi B est commutabilis
16.3 Guadagno:0-100, passo 2
16.4 Modellum Display:una imago,duae imagines,quattuor imagines
16.5 Rotatio Imaginis:Axis X/Y/Z
16.6 Visibilitas Multi-slice
16.7 Inversio Luminis&Umbrae
16.8 Laevis:0-4, 4 gradus
16.9 Limen:0-129, Gradus 3
16.10 Transparentia:1-509, Gradus 10
16.11 Genus Rerum Pictarum:4 genera, Superficies, maximus, minimus, prospectiva
17: Imago Extensa
17.1 Guadagno:0-100, passo 2
17.2 TGC:8 segmenta regulabilia
17.3 Punctum foci maximum:≥7, quod per totum cursum movere licet.
17.4 Reductio macularum: 0-5, 5 gradus
17.5 Compositio Spatii: 0-2, 2 gradus (Proboscis Linearis: 3 gradus, non sustinet proboscidem cardiacam)
17.6 Ambitus Dynamicus: 30-180, 35 gradus, Gradus 5
17.7 Densitas Lineae: Infima, Media, Maxima, 3 gradus
17.8 Correlatio formae: 0-4, 4 gradus
17.9 Reductio strepitus: 0-5,5 gradus
17.10 Intensificatio marginis: 0-5, 5 gradus
17.11 Vis soni: 2-10, 9 gradus
17.12 Carta grisea: 0-67, 67 gradus
17.13 Color fictus: 0-67, 67 gradus
17.14 Stilus imaginis: Molle-Comparatio, 2 gradus
17.15 Gradus extendere: Maximus 72 gradus
Sondam convexitatis: 9 gradus
Sonda transvaginalis: 72 gradus
Sondam microconvexitatis: 29 gradus
Sonda cardiaca:40 gradus
sonda voluminis 4D:17 gradus
  PS: Tabula praesentat in tempore reali indicem vocis, frequentiam sondae, ambitum dynamicum, colorem ficticiam, scalam griseam et alia undecim parametra quae possunt regi
  PS: Cum ambitus scandendi sondae ad maximum pervenit, spatium compositum nihil est.
18: Functio mensurae et analysis:
18.1 Mensura generalis: distantia, area, ellipsis, linea crux, angulus, ratio distantiae, volumen, Volumen (ellipsis), ratio areae, diametrus, articulus angulus
18.2 Cardiacus: Spectrum involucrum automaticum, LV, Diametrus arteriae pulmonalis principalis, RVEDd, RVEDs, LVM, LAV, HR, MVF, AO, AR, LVOT, TVF, Valva pulmonalis, Venae pulmonales, RV, Doppler fetus cordis sonus, LVET, LVM, LVMI, AV
18.3 Vascularis: carotidis intima (IMT), longitudo ratio stenosis, area ratio stenosis, IMT (paries posterior), IMT (paries anterior)
18.4 OB: Fetalis consuetudo, AFI, TW, GS, CRl, OFD, HL, ulna, NT, Fibula, Nbonel, Radialis, Tibia
18.5 GYNAECOLOGIA: uterus, cervix, corpus uteri/cervix uteri, vena ovarica sinistra, vena ovarica dextra, folliculus dominans, crassitudo intimae
18.6 UROLOGIA: prostata, urina residua, ren sinister, ren dexter, vena suprarenalis sinistra, vena suprarenalis dextra, testis sinister, testis dexter, vesicula seminis sinistra, vesicula seminis dextra
18.7 ABDOME: iecur, CHD, diametrum venae portae, vesicula fellea, pancreas, splen, diametrum internum aortae abdominalis, ren
18.8 PARVAE PARTES: Thyreoidea
18.9 PACCVUM SOFTWARE: Paccvum mensurae, pacvccum software, pacvccum software gestionis recordorum medicorum
19: Systema administrationis graphicorum et litterarum
19.1 Aedificium hospitis in duobus discis duros (SSD 120+1T), Celeriter et stabiliter incipit
19.2 Repraesentatio cinematographica: ≥1200 imagines
19.3 Systema administrationis informationum internarum: potest registrare numerum patientis, nomen, numerum examinationis, diem examinationis et cetera, et potest quaeri et administrari per numerationem, numerum examinationis, nomen et cetera.
19.4 Genus relationis est 16
19.5 Unus clavis velox relatio graphic et textus administratio
20: Interface
20.1 Interfacing USB: 4
20.2 Interfacing HDMI: 1
20.3 Interfacing RJ-45:1
20.4 Interface filum terrae:1
20.5 DVD RW:1
21: Configurationis
21.1 Type plaustralis systema diagnosticum ultrasonicum totum digitale coloris Doppler
21.2 Sonda: sonda ad array convesso (standard), sonda lineare (opzionale), sonda transvaginale (opzionale), sonda cardiaca (opzionale), sonda volumetrica 4D (opzionale)
21.3 ≥13 manopole di regolazione rapide
22: Technologia, servizio post-vendita e altri requisiti
22.1 Dopo l'accettazione, la garanzia è gratuita per due anni (Fornire certificato di garanzia del produttore)
22.2 Fabricator habet certificationem ISO13485 et certificationem CE EU.

Productum Relatum

×

Get in touch

Have Questions about Medical Equipment?

Nostrae venditionesque turmae professionales consultationem tuam exspectant.

Accipe Citatum