1.YJ-X501 Machina Radiographica Digitalis.

2.Principales componentes: Generátor HV, Tubus Radiographiae X, Tabula, Stans Bucky, Cable HV, Collimator, Arca Electrica.

Brochure Producti: Descarga

  • Video
  • Introductio
  • Parametrum
Video

Introductio

1. Machina Radiographica Digitalis YJ-X501 utilitatis praecipuae est in examinationibus medicis mammillarum, membrorum, pelvis et lumborum hominum.
2. Generatio HF & HV a microcomputatore controlleta, conditiones expositionis stabiles et accurate sunt, et rotatio
angulus accurate definitur, quod necessitates clinicalium multiformium positionum photographiae implent.
3. Interfacing operativa cum display cristal liquidus, simplex et expedita positio informationis et parametri expositionis configurationis,
tubus radii X et bucky interconnecti sunt, facile ad focum dirigere.
4. Protectio capacitatis tubi et diagnosing sui ipsius defectuum in forma codicis ostenditur, ut usus et conservatio facilior sit.

Parametrum
Main
configurationis
Parametri technici
Tubus X radii 1.Modelus tubi X radii XD52-30.5/125KV/XD52-10.40/150KV
2.Focus: Duplex focus 1x1, 2x2
3.Velocitas rata anodis est 2800r/min

Multifunctionalis
Tabula radiologica
1. Motus superfici tabulae: seratura electromagnetica cum pedita liberatione
Verticaliter: ±560m. Horizontaliter: ±120mm
2. Reticulum X-fixum: Lineae: 40L/cm, Ratio reticuli: 10:1, F.D: 100cm.
Ambitus motus: 610mm
3. Specificatio radiographica: 5"x7", 8"x10", 10"x12", 11"x14", 12"x15", 14"x14"
14*x 17
4. Distantia a superficie tabuli ad pelliculam: 75mm
5. Altitudo tabuli: 700mm
6. Motus columnae: 180 omnis 90 positionis, cursus longitudinalis 1500mm.
7. Motus columnae: 180 omnis 90 positionis, cursus longitudinalis 1500mm
Collimator radii X Maximus campus irradiationis: SID(FFD)=1000mm horas, non minus quam 430 mmx 430 mm
Minimus campus irradiationis: 0×0 mm
innatus filtrum: 1 mm·Al/75kVp
Supplementum filtrum: 1 mm·Al et 2 mm·Al
Modus folii plumbea: manualis
Vis operativa: 24V AC/DC, 150 W (Infima voltus securitas)

HV-Generator
Potentia
Copia
Voltus: 380V/220V±10%
Frequentia: 50HZ±1HZ
Resistentia: ≤0.3Ω
Radiographia
Morbi laoreet
vertens Frequens: ≥30kHZ
Vires:≥50kW
Ignis Current:16-500mA, Gradus possunt regulari
Ignis Voltage:45-125KV, Gradus est 1KV
Tempus Expositionis:0.01-6.3S, 26 gradus
Modus Selectionis:64 genera conditionum expositionis sunt conservata,
operator potest libere eos eligere
Capacitas memoriae APR: 2400 data

Productum Relatum

×

Get in touch

Have Questions about Medical Equipment?

Nostrae venditionesque turmae professionales consultationem tuam exspectant.

Accipe Citatum