45L B Class Table Top Autoclave
- Introduction
- Parameter
Introduction
YJ-TPV45 Class B autoclave
High Performance Laboratory Equipment Table Autoclave Steam Sterilizer
Adopt European Class B standard, suitable for all kinds of packaging, unpacked, solid and internal plumbing machinery.
Built-in independent steam generator. Sterilization, drying time can be manually adjusted, so that sterilization, drying effect to achieve the best working state.
Features
- The third vacuum and the first vacuum are integrated into one, which is convenient for the user to disinfect different items.
- Built-in two vacuum pumps for faster sterilization time.
- Built-in independent steam generator.
- The sterilization time and drying time can be adjusted freely.
- Newly added separation and drying procedure (optional).
- Dual gate protection locking system is superior.
- Oversized liquid crystal display to make the state of the data displayed more intuitive.
- Built-in printers make it easy to print sterilized records. (optional).
- Built-in USB interface, flexible choice of sterilization data recording and storage mode
Parameter
|
Sterilization roon size(cm) |
Φ31.9*61.5 |
|
Outline dimension(cm) |
94*59*57.5 |
|
Product form |
Desktop |
|
Heating mode |
electrical heating |
|
Power supply |
AC220V,50Hz |
|
Sterilizing chamber material |
The sterilizing chamber is 304 anticorrosive stainless steel with thickness ≥ 3mm, safety door thickness ≥ 15mm, hydraulic test ≥ 0.8mpa. which exceeds the national standard of YY0646-2008 design. |
|
Outer box material |
Carbon steel (1.5mm thick) baking powder |
|
Work environment |
0-50ºC |
|
Working pressure |
-80kpa~200kpa |
|
Sterilization humidity |
≥80% |
|
Maximum pressure resistance |
-120kpa~260kpa |
|
Sterilization temperature |
121ºC-135ºC adjustable |
|
Vacuum mode |
Three pre-vacuum to ensure faster heating, sterilization more thorough. |
|
Over voltage protection program |
When the sterilizing chamber pressure reaches 220 ±5kPakPa, there are cues and automatic pressure relief. |
|
Pressure sensor |
The inner pressure sensor automatically detects the pressure inside the cavity to ensure the accuracy and efficiency of the pressure. |
|
Temperature sensor |
The built-in temperature sensor automatically detects the temperature inside the cavity to ensure that the temperature in the cavity is within the accurate range of ±3 ºC. |
|
Sterilization mode |
Bare equipment, cotton yarn, wrapping equipment, plastic and rubber equipment products, the default working temperature is 135 ºC. |
|
Sterilization time at 135 ºC |
36 minutes(Preheat 12 minutes, vacuum 4 minutes, sterilization 4 minutes, dry 16 minutes) |
|
Sterilization time at 122 ºC |
56 minutes(Preheat 8 minutes, vacuum 4 minutes, sterilize 5-20 minutes, dry 20 minutes) |
|
Alarm system |
High and low temperature alarm system |
|
Category |
Class II medical devices |