130L H2O2 Low Temperature Plasma Sterilizer
1. Cost effective
2. Fast and efficient-average cycle length 32min Simple installation
3. Large capacity
4. USB interface
Product Brochure:DOWNLOAD
- Video
- Introduction
- Parameter
Video
Introduction
Parameter
|
Item |
Specifications |
|
Total volume |
130L |
|
Effective volume |
130L |
|
Product Size |
1660*860*1060(mm) |
|
Sterilizer size |
790*412*400(mm) |
|
Sterilizer structure and material |
Square cavity with stainless steel |
|
Operation method |
LCD touch screen touch operation |
|
Sterilization method |
the volume of sterilized items and release unequal amounts of H2O2. |
|
Disinfectant |
|
|
Sterilization speed |
1 standard sterilization ≤35 minutes;
|
|
Sterilization mode |
|
|
Sterilization temperature |
50 ℃ ± 5 ℃, the program will automatically terminate when sterilization is over temperature |
|
Sterilization effect |
The sterilization program can effectively sterilize stainless steel tubes with a diameter of 1mm and a length of 500mm and PTFE tubes with a diameter of 1mm and a length of 2000mm. |
|
Main control system |
|
|
Sterilization records |
1. The pressure, time, cycle mode, process stage, etc. of the sterilization process are automatically displayed on the touch screen, and the working process is automatically printed. |
|
|
|
Alarm system |
1. Automatic alarm system, and touch screen text to display alarm content. With over-humidity fault alarm, hydrogen peroxide supply fault alarm, sterilization chamber temperature abnormal alarm, injection heater temperature abnormal alarm, sterilization door fault alarm |
|
2. Sterilization pressure and temperature with alarm settings. |
|
|
3. Maintenance alarm prompts for key components such as vacuum pump oil change. |
|
|
Sterilization room door |
≥18mm. |
|
Vacuum pump |
The vacuum pump has low noise, low emissions, fast evacuation, high stability, low maintenance costs, and an evacuation rate of 18 liters / second |
|
Sterilization residue |
Non-toxic |
|
Vacuum pump oil replacement time |
Use in a clean air environment, change every 180 days |
|
Impact on medical staff |
The ultraviolet rays generated by the plasma are completely shielded from the operator and completely invisible to the naked eye. |
|
Fully equipped with supplies |
Plasma special chemical instruction card, chemical instruction label, packaging bag, sterilant, self-contained biological indicator. |
|
Power Supply |
AC220V,50Hz、3.6KW |
|
The key components |
Vacuum pump, pressure transmitter, solenoid valve, air filter, embedded microcomputer, temperature controller, relay, etc. |
|
Work environment |
Install and make use of it at indoor Temperature: 5℃~40℃ Humidity : 30%~80% Mains voltage fluctuation:110V±10% Altitude is at most 2000m Transient overvoltage category:Ⅱ Rated pollution degree: 2 |
EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
HI
IT
JA
KO
NO
PL
PT
RO
RU
SV
CA
TL
ID
SR
SK
SL
VI
GL
HU
TH
TR
FA
MS
KM
LO
LA
MY
UZ
KY
























